One-stop fire protection supply · Tianjin, China · est. 2018
FM / UL / CE / LPCB / VDS
Ring Hanger
Home / Products / Pipe Hangers / Ring Hanger

Ring Hanger

Suspension of non-insulated stationary pipe lines. The knurled insert nut allows vertical adjustment after installation.

FunctionSuspension of non-insulated stationary pipe lines. The knurled insert nut allows vertical adjustment after installation.
MaterialCarbon steel
FinishElectro-galvanized / Pre-galvanized
ApprovalsFM Approved / UL Listed
Max. Temperature343°C (650°F)
OrderingSpecify size
Request a quote All hangers

About the ring hanger

What the ring hanger does on a fire line, and how to specify it.

Where a ring hanger sits in a fire line

The ring hanger is the default way to hang a straight run of bare fire pipe off a concrete deck or a steel beam. The U-shaped member wraps the outside of the pipe and the threaded rod carries the load up to the anchor. It is made for stationary pipe, meaning a run that does not expand and contract under temperature, which is exactly how most sprinkler branch lines and mains behave once the system is charged and idle.

Why the knurled insert nut is there

The insert nut is knurled so it can be gripped by hand or with a wrench. That is the adjustment you actually use on site: anchor the rod, let the pipe hang, level the run, then take up the nut to lock the height. You are setting the line once and leaving it alone, and the nut is the part that makes a clean, repeatable set possible without cutting or re-threading.

Material, finish and the fire rating

It is carbon steel, electro-galvanized. The zinc layer is what keeps the hanger from rusting ahead of the pipe in the damp, exposed locations fire rooms tend to be: plant rooms, roofs, basements. The item is rated to 343 degrees C (650 F), so the support holds its place through a sustained fire event instead of losing strength while the pipe it carries is doing its job. The marked items are FM Approved and UL Listed.

Ordering it right

Send the line with the rest of the assembly rather than as a single part. State the size against the pipe outside diameter it serves, the finish, and the count. Pair it with the matching threaded rod, nuts, washers and anchors from the same range, and flag whether the design needs the fire-rated, FM/UL marked version, so the support arrives with the pipe instead of chasing it later.

FAQ

Can a ring hanger be used on insulated pipe?

No. The ring is shaped for bare, non-insulated pipe. An insulated run needs a hanger that clears the insulation jacket so it is not crushed at the support.

Is it rated for fire service?

Yes. The marked ring hanger is FM Approved and UL Listed, rated to 343 degrees C (650 F).

How do I specify it?

Match the hanger to the pipe outside diameter and state the finish. Order the matching threaded rod, nuts and anchor for the run as a set.