Suspension of non-insulated pipe lines, horizontal or vertical. Two configurations: with EPDM rubber strip, or without (rubber strip omitted on request).
What the double screw bundle does on a fire line, and how to specify it.
A double screw bundle clamps the pipe with two rods working through a central member. It will hold a run horizontally or vertically, which is why it shows up on both the straight pipe work and the risers. The two-rod arrangement keeps the pipe centered and resists it rocking side to side at the support.
There are two configurations. With the EPDM rubber strip, the bundle isolates vibration and noise, and keeps the clamp from bearing hard on the pipe. Without it, the bundle is the all-steel version. The temperature rating follows the rubber: the rubber version is rated to -20 to 110 degrees C, and the no-rubber version is rated to 343 degrees C. Choose the version for the location, and say so in the order.
Carbon steel, electro-galvanized, with the EPDM strip added where specified. The finish matches the rest of the hanger range so the support does not corrode ahead of the pipe it holds.
Send the line with the rest of the assembly rather than as a single part. State the size against the pipe outside diameter it serves, the finish, and the count. Pair it with the matching threaded rod, nuts, washers and anchors from the same range, and flag whether the design needs the fire-rated, FM/UL marked version, so the support arrives with the pipe instead of chasing it later.
Use the EPDM version where you want vibration or noise isolation, rated to -20 to 110 degrees C. Use the no-rubber version where the line can see fire-event temperatures, rated to 343 degrees C.
Yes. The double screw bundle is made for horizontal or vertical runs.
The marked items are FM Approved and UL Listed. Check the rubber specification, since the rated temperature depends on whether the strip is fitted.
Selection guides and field notes on fire protection pipe, fittings and supports.
A fire sprinkler system can be perfect on the design paper and still fail in the field if the pipe is not held up properly. The pipe, the fittings, the valve, a…
Read →2026-09-30Pipe hanger spacing is the quiet part of a fire line spec. The hangers are there, the pipe is up, and nobody thinks about the interval again until the line star…
Read →2026-10-01An earthquake does not care about your sprinkler system. It shakes the building, the building moves, and the pipe moves with it. If the pipe swings far enough, …
Read →2026-10-03Nobody photographs the hangers on a fire line. Everybody inspects them. I have stood on site while an inspector ran a finger down the support schedule, then wal…
Read →2026-10-12An earthquake does not break a sprinkler pipe. It moves the building around the pipe. The joint that lets the pipe move a little, and the brace that stops it moving too much, are the two halves of the same system.
Read →Send your bill of materials or drawing — we confirm spec, cert and lead time, then ship the full package.